3DPrinting
3DPrinting is a place where makers of all skill levels and walks of life can learn about and discuss 3D printing and development of 3D printed parts and devices.
The r/functionalprint community is now located at: [email protected] or [email protected]
There are CAD communities available at: [email protected] or [email protected]
Rules
-
No bigotry - including racism, sexism, ableism, homophobia, transphobia, or xenophobia. Code of Conduct.
-
Be respectful, especially when disagreeing. Everyone should feel welcome here.
-
No porn (NSFW prints are acceptable but must be marked NSFW)
-
No Ads / Spamming / Guerrilla Marketing
-
Do not create links to reddit
-
If you see an issue please flag it
-
No guns
-
No injury gore posts
If you need an easy way to host pictures, https://catbox.moe may be an option. Be ethical about what you post and donate if you are able or use this a lot. It is just an individual hosting content, not a company. The image embedding syntax for Lemmy is ![](URL)
Moderation policy: Light, mostly invisible
view the rest of the comments
If you know your deviation, I assume you have a bed probe, right? Are you using your bed mesh? Can you share your start GCode?
[gcode_macro PRINT_BEGIN] description: Begin printing with nozzle wipe gcode: M300 P500 {% set BED_TEMP = params.BED_TEMP|default(60)|float %} {% set EXTRUDER_TEMP = params.EXTRUDER_TEMP|default(210)|float %} BED_MESH_PROFILE LOAD=default M104 S{EXTRUDER_TEMP} M140 S{BED_TEMP} {% if printer.toolhead.homed_axes != "xyz" %} G28 {% endif %} #BED_TILT_CALIBRATE G1 X80 Y240 Z5.0 F3000 ; position nozzle right next to wipe pad M190 S{BED_TEMP} M109 S{EXTRUDER_TEMP} M300 P500 G4 P50 M300 P500 S1500 G1 Z-0.1 ; lower nozzle before wiping G1 X90 F500 ; wipe nozzle across pad in X direction G1 Y235 F500 ; wipe nozze in Y direction G1 Z3 ; lift nozzle to 3mm G1 X90 Y-3 F6000 ; move nozze to front-left center of bed for purging G1 Z0.28 ; lower nozzle to 0.28mm G1 X120 E25 F200 ; extrude 25mm of filament in a 40mm line G92 E0 ; reset extruder position G1 E-1 F2100 ; quickly retract filament 3mm G1 X135 F10000 ; quickly move away from purge
G92 E0
Could you also post the [bed_mesh] section of printer.cfg?
Sure
[bed_mesh] speed: 150 horizontal_move_z: 5 mesh_min: 25, 17 mesh_max: 220, 200 algorithm: bicubic bicubic_tension: 0.5 probe_count: 6, 6
What type of probe and what's the config on it?
Is what I've got my pinda probe configured with, was playing around with sample tolerances like I have on my printer with a tap probe but I just found the inductive probe has a lot of variation, I added more samples to hopefully average out that error.
Is my mesh setup, based on a mk3s klipper config. Meshes look a little odd but I ran some bed level prints fine and just ran a full plate of abs with pretty consistent 1st layer.