I have some TE modules that run at 10W or so and can cool 250mW at I think -50°C to -70°C so they can be awful.
I see. You have a huge delta-T there, which is unnecessary for keeping a filament box dry.
A couple sources say PA6 (a random moisture-sensitive filament) should be stored below 20% , or at 15% relative humidity. In a 66f/19c room temperature, that 15% RH would be a dew point of 17f/-8c according to dpcalc.org. In a 74f/23c room, 15% is a dew point of 23f/-5c; as you warm up the temperature further the dew point to achieve a particular RH increases (which is why we heat air to dry things).