this post was submitted on 16 Sep 2024
55 points (98.2% liked)

No Stupid Questions

35950 readers
2186 users here now

No such thing. Ask away!

!nostupidquestions is a community dedicated to being helpful and answering each others' questions on various topics.

The rules for posting and commenting, besides the rules defined here for lemmy.world, are as follows:

Rules (interactive)


Rule 1- All posts must be legitimate questions. All post titles must include a question.

All posts must be legitimate questions, and all post titles must include a question. Questions that are joke or trolling questions, memes, song lyrics as title, etc. are not allowed here. See Rule 6 for all exceptions.



Rule 2- Your question subject cannot be illegal or NSFW material.

Your question subject cannot be illegal or NSFW material. You will be warned first, banned second.



Rule 3- Do not seek mental, medical and professional help here.

Do not seek mental, medical and professional help here. Breaking this rule will not get you or your post removed, but it will put you at risk, and possibly in danger.



Rule 4- No self promotion or upvote-farming of any kind.

That's it.



Rule 5- No baiting or sealioning or promoting an agenda.

Questions which, instead of being of an innocuous nature, are specifically intended (based on reports and in the opinion of our crack moderation team) to bait users into ideological wars on charged political topics will be removed and the authors warned - or banned - depending on severity.



Rule 6- Regarding META posts and joke questions.

Provided it is about the community itself, you may post non-question posts using the [META] tag on your post title.

On fridays, you are allowed to post meme and troll questions, on the condition that it's in text format only, and conforms with our other rules. These posts MUST include the [NSQ Friday] tag in their title.

If you post a serious question on friday and are looking only for legitimate answers, then please include the [Serious] tag on your post. Irrelevant replies will then be removed by moderators.



Rule 7- You can't intentionally annoy, mock, or harass other members.

If you intentionally annoy, mock, harass, or discriminate against any individual member, you will be removed.

Likewise, if you are a member, sympathiser or a resemblant of a movement that is known to largely hate, mock, discriminate against, and/or want to take lives of a group of people, and you were provably vocal about your hate, then you will be banned on sight.



Rule 8- All comments should try to stay relevant to their parent content.



Rule 9- Reposts from other platforms are not allowed.

Let everyone have their own content.



Rule 10- Majority of bots aren't allowed to participate here.



Credits

Our breathtaking icon was bestowed upon us by @Cevilia!

The greatest banner of all time: by @TheOneWithTheHair!

founded 1 year ago
MODERATORS
 

I live on the 14th floor of a 30 story apartment building and so far, I've been bleeding my radiators myself.

This usually worked and after bleeding I had a fully functioning radiator, 100% filled with water.

However, last time I tried bleeding, it would only fill up to 25% of its volume, it's like there's no pressure in the circuit.

Am I doing something wrong?

top 14 comments
sorted by: hot top controversial new old
[–] [email protected] 65 points 2 months ago (1 children)

A water central heating system is a closed loop system that is under pressure. This means the water in it is circulated around and around the system and is cut off from other water supplies under normal operation. Naturally, slow leaks happen and gas can enter the system in various ways so occasionally this needs to be released from the system. Any gas in the system naturally collects at the highest points along the path - which tend to be the radiators.

When you bleed a radiator you are opening the system to the outside and hopefully where the gas has accumulated. Since the system is under pressure it forces the gas out of the system to equalize the pressure with the outside. This will cause the pressure of the system to drop and eventually it will stop.

However there should be a control valve somewhere, typically on/near the boiler that connects the central heating system up to the mains water supply. You can open this valve to cause water to flow into the central heating system and pressurize it and really this should be done every time you bleed the radiator a significant amount.

In apartments though you might find that you are on a building wide circuit, or you might have one isolated for your apartment. If you have a boiler in your apartment then you are likely on a closed system and should be able to equalize the pressure yourself. If it is building wide you need to talk with your building manager.

Note that you should not need to bleed your radiators that often. Once every several years should be more than enough. If you are doing it frequently then you likely have a large leak in your system and likely want to get someone to check that out.

[–] ODuffer 12 points 2 months ago

Great answer, there should also be a pressure gauge somewhere on the boiler. As mentioned, this is really for your building manager though.

[–] rockSlayer 26 points 2 months ago* (last edited 2 months ago)

Having lived in a house with radiators, bleeding registers is like a once every 5 years type of task. There's a much larger leak in the system, you should talk to your apartment manager.

[–] [email protected] 20 points 2 months ago* (last edited 2 months ago)

Plumber here.

It's a closed circuit. When you're bleeding out air the pressure in the system drops. When there's no sufficient pressure the water wont reach the upper floors.

Under normal circumstances the system is bled of air once and then they add more water untill the optimal pressure is reached and that's it. You shouldn't need to bleed air or add water ever again. The fact that you keep bleeding it indicates that new air is introduced somehow. Usually this means there's a leak and someone keeps topping it up with fresh water which contains air that then need to be bled out again.

Alternatively the issue could also be non-plumbers like yourself who keep bleeding the radiators on their own and then the maintenance keeps adding more water and wondering why the pressure always drops again. In my part of the world it's forbidden for the residents to bleed their radiators for this very reason.

Also, the radiator lines are usually steel. The reason they don't rust is lack of oxygen. Now with constantly more water and thus air being added to the system the corrosion keeps on advancing.

[–] [email protected] 11 points 2 months ago

I'd expect that the person to ask would be the building manager.

[–] [email protected] 3 points 2 months ago (1 children)

That depends entirely on how the system is set up. I would only ever consider increasing the amount of water in the system if I was absolutely certain that my apartment was on a completely separate and closed circuit than the other apartments. You should contact the janitor or whatever it's called.

[–] [email protected] 4 points 2 months ago* (last edited 2 months ago) (1 children)

Usually, at the ~~heating~~ boiler, there is a junction for a hose with a valve and close by a pressure meter. If the pressure is too low, the janitor (not you) should fill up the heating system with water until the pressure is sufficient. Ideally, the pressure should be checked again after bleeding the radiators.

[–] [email protected] 2 points 2 months ago (1 children)

Yup, that's how it's done when there's a heat exchanger.

However there's a reason why the boiler room is usually locked off in a 30 story building. Bleeding a radiator might be relatively harmless, but there's no way of knowing what the pressure is supposed to be without knowing the entire system.

Some (lower) buildings might even have direct district heating without an exchanger, which is absolutely no go to even bleed.

[–] [email protected] 2 points 2 months ago* (last edited 2 months ago)

However there's a reason why the boiler room is usually locked off in a 30 story building. Bleeding a radiator might be relatively harmless, but there's no way of knowing what the pressure is supposed to be without knowing the entire system.

Exactly. That's why either the janitor knows the correct pressure or they need to call a technician. Definitely not something to have hands on oneself in a building that's not yours.

[–] [email protected] 3 points 2 months ago* (last edited 2 months ago)

How do you know how much it's filled?

Also, hot water heat works differently than steam, and many steam systems have been converted to hot water, so it's not easy to know just by looking at a radiator.

As other people have said, let the maintenance folks handle it. They know the system.

[–] [email protected] 2 points 2 months ago (1 children)

There needs to be space someplace in the system since water expands when it warms. Sometimes that space is in the radiators andso bleeding needs to not let all the air out, for this reason you should get maintenance toefix the problem if one exists so they can balance the system.

[–] [email protected] 5 points 2 months ago (1 children)

That's what expansion tanks are for. There shouldn't be any air in the system itself.

[–] [email protected] 3 points 2 months ago

Older systems have been known to use the radiators as the expansion tank. this would not meet modern code but plenty of old systems exist.

[–] [email protected] 1 points 2 months ago

I have only done it with steam type and honestly I felt it was one of those more art than science things. buying the adjustable valves was nice to control temp a bit.