They are bigger than I was able to capture on camera beauty of water heater being in the way.

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 6 points 2 years ago (2 children)

Is it leading to an outdoor location? Or leading indoor? If so I would just use grey putty, or grey duct seal I think it’s called.

[–] [email protected] 4 points 2 years ago

Monkey gunk is what we call it for some reason.

[–] AnotherPerson 2 points 2 years ago (1 children)

Leading to an indoor wall from a garage.

[–] nowwhatnapster 6 points 2 years ago

You have what appears to be a BX cable penetrating and indoor wall to a garage. This needs fire stopping to meet code.

Here is Hilti's drawing showing the wall assembly and how it can be fire stopped with their products. The optional metal conduit pictured would make it cleaner but also require disconnecting the cable.

https://files-ask.hilti.com/original/eg/eg5q3zprsz.pdf