this post was submitted on 19 Sep 2023
9 points (100.0% liked)

Plumbing

202 readers
1 users here now

A place for Plumbers and those interested in Plumbing to ask questions and discuss the trade.

Community guidelines:

If you have a plumbing question please include a picture in your post.

If you have a question such as "does this look correct?" please include the code your area adheres to. If you're not sure please include state/province/country you're in. Codes can vary state to state and what's wrong in one area may be perfectly acceptable in another.

Just as codes vary, prices do too. That's why we won't discuss any pricing because there's so many factors that can't or shouldn't be conveyed to strangers over the internet.

founded 2 years ago
MODERATORS
 

Since we moved in we've noticed a sewer smell from time to time. I had a plumber come and identify this laundry discharge pipe not having a trap as the culprit. He ended up ghosting me so I cut more into the wall and found this black thing I couldn't identify until now (I think). I guess it's a drum trap after doing some more googling. If it's working as designed I guess it's supposed to hold water in and not let sewer gas through? but we definitely have a problem with the smell coming from this laundry room. Is this maybe not to culprit and I could leave it alone? I'm considering cutting it out and just connecting PVC the whole way through. Any recommendations or thoughts would be much appreciated.

you are viewing a single comment's thread
view the rest of the comments
[โ€“] Bigtiddygothgrany 2 points 1 year ago (1 children)

Wow there's a lot going on here, yes that is a drum trap, check if there's a floor drain that's dried out in your laundry room and pour some water in it. I'm surprised your washer doesn't spill over because a minimum standpipe is 18 inches in most areas and yours looks a lot less than that. Also drum traps are illegal in most codes now.

[โ€“] maniajack 1 points 1 year ago* (last edited 1 year ago)

No floor drain from what I can find, and the main pipe out to the septic is about a foot above the floor so I don't think there would be anything lower. The washer wall box is the only source of the smell I can figure, it definitely smells but yeah I don't know how it's not filling up with water, maybe siphoning out? I also can't find a pipe going up to a vent. Just to the left is the main pipe drainage. If I do replace the crappy drum trap I plan to go down the 18+ inches and then back over but I guess I should get a vent in too? I apparently can use the other side of the laundry wall box with an air admittance valve. This is mostly from me watching this vid: https://youtu.be/EzMURfc3Fgo?si=SrDV8A779xvmB-k4

Thanks for the reply, any other feedback welcome