this post was submitted on 01 Aug 2023
456 points (97.9% liked)

Technology

60023 readers
3616 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related content.
  3. Be excellent to each another!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, to ask if your bot can be added please contact us.
  9. Check for duplicates before posting, duplicates may be removed

Approved Bots


founded 2 years ago
MODERATORS
 

Heat pumps sold so fast in Maine, the state just upped its target::undefined

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 3 points 1 year ago* (last edited 1 year ago)

That is refrigerant dependent. For example R744 (plain old CO2) works well efficiently down to -4F, -20C and down to -40C/-40F just with some efficiency drop.

Main issue is CO2 needs a constant high pressure heat pump system, since it needs to be highly pressurised to be fluid at all. In ambient it sublimates (goes straight between gas and solid aka dry ice).

However that is a solved issue. Working CO2 heatpumps are off the self commercially available these days. Just still little more expensive as I understand. However prices should come down with production economies of scale, upon CO2 taking over due to pollution, toxicity, flammability, green house considerations. He nastier chemicals weren't used for being all the ways superior, but due to it being easier to make the heat pump units (be they running in heating or in cooling) due to lower pressure requirements.

Since CO2 and ammonia were the original refrigerants. Used in large ice production facilities early on, where their specific needs weren't issue even for earlier technology. Large, purpose built, stationary industrial facility had no problem accommodating the needed massive pressures by just really massive and heavy pipework.

However these days the propeller head people developed micro channel tubing and heat exchangers to keep the high pressure CO2 in control.