Annoyingly, the RB5009 doesn't have a voltage regulator on its PoE-out ports. So it outputs ~48V, but other Mikrotik devices that support PoE-in only support ranges like 20-34V.

There is a solution! And I wanted to share it with you guys as my first post :)

48V-to-24V in-line convertor: https://www.aliexpress.com/w/wholesale-poe-Converter-48V-to-24V.html

This will convert the output from the RB5009 to 24V. Tested with PoE-out on RB5009UPr+S+ and PoE-in on CSS106-5G-1S.

The RB5009 is a fantastic device.

top 4 comments
sorted by: hot top controversial new old
[–] [email protected] 2 points 1 year ago

I hate all the incompatible version of PoE. That's stung me in the past!

But I agree, mikrotik devices are phenomenal.
They are currently working in hardware QoS queues for the CRS series, which is gonna be huge for me!

[–] [email protected] 1 points 1 year ago (1 children)

I have the non-PoE version of the RB5009 and have been thinking about getting a second one (w/PoE) to replace a switch.

Can you explain briefly how this converter is used? Do you power the entire device with it, making all PoE outputs 24v?

[–] [email protected] 1 points 1 year ago (1 children)

It is a per-port convertor. In my case, I want to power another switch by the RB5009. The other switch being the CSS106-5G-1S.

So I have RB5009:eth7, connected to CSS106:eth1. I'm expecting power output from the RB5009 to power CSS106, however by default the RB5009 outputs 48V and so is incompatible.

The convertor male end plugs into the RB5009, and then the other device plugs into the female part of the convertor. It then in-line converts 48V to 24V.

[RB5009]===[CONVERTOR]===[POE-POWERED-DEVICE]

[–] [email protected] 1 points 1 year ago

Ah, the search results for me were not related to PoE, but with a different search I see what you mean now.