this post was submitted on 18 Jun 2023
44 points (97.8% liked)

Australia

3376 readers
236 users here now

A place to discuss Australia and important Australian issues.

Before you post:

If you're posting anything related to:

If you're posting Australian News (not opinion or discussion pieces) post it to Australian News

Rules

This community is run under the rules of aussie.zone. In addition to those rules:

Banner Photo

Congratulations to @[email protected] who had the most upvoted submission to our banner photo competition

Recommended and Related Communities

Be sure to check out and subscribe to our related communities on aussie.zone:

Plus other communities for sport and major cities.

https://aussie.zone/communities

Moderation

Since Kbin doesn't show Lemmy Moderators, I'll list them here. Also note that Kbin does not distinguish moderator comments.

Additionally, we have our instance admins: @[email protected] and @[email protected]

founded 1 year ago
MODERATORS
 

Will those in the southern states cope? Could you switch?

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 3 points 11 months ago (2 children)

We built our house specifically to not have mains gas. Large double-glazed picture windows on the north side of the house, Solar and a Battery, decent insulation. Large capacity reverse cycle A/C with the condensers on the south side of the house.

The a week before handover, the Site Supervisor told us that they ‘mistakenly’ budgeted for “electrical assist” hot water instead of full electric. They would need to add Gas, but they would pay for the connection. We argued with them. They argued back. It escalated all the way to the CEO of the Building Company. The Site Supervisor kept insisting that it was impossible to have full electric hot water, that is was cost-prohibitive to install, cost-prohibitive to run and anyone who would not want gas hot water was a fucking idiot. The CEO explained to the Site Supervisor that his own house had Full electric, two Tesla Power-walls and an extensive solar array and hadn’t had to pay for Gas or Electricity since it was built. He then calmly fired the Site Supervisor and instructed the Regional Manager to authorise the Full electric hot water with no extra charge to us.

[–] [email protected] 1 points 11 months ago (1 children)

This is a crazy story. Most houses in northern Australia have full electric hot water. Very rare to have town gas and bottles is often painful.

[–] [email protected] 1 points 11 months ago

We had all sorts of problems with the build. It had minimal to do with the company and everything to do with the Site Supervisors(s).

Another example was the Colourbond roof. We specifically wanted a light colour (to reflect heat in summer), with Woodland Grey gutters (to contrast with the roof and complement the render). We turned up one night after work and they had done the whole roof in Woodland Grey. We pointed out this observation and found out that the Site Supervidor had changed the purchase order because he “thought that Woodland Grey would look better”.

His suggested remedy was to repaint the roof and even came into my workplace during work hours to try to con me into authorise the incorrect roof colour.

In the end they had to tear down the Woodland Grey and re-clad in Surf Mist.