this post was submitted on 27 Aug 2024
18 points (90.9% liked)

Ask Electronics

3173 readers
1 users here now

For questions about component-level electronic circuits, tools and equipment.

Rules

1: Be nice.

2: Be on-topic (eg: Electronic, not electrical).

3: No commercial stuff, buying, selling or valuations.

4: Be safe.


founded 1 year ago
MODERATORS
 

cross-posted from: https://lemmy.dbzer0.com/post/26703241

This diagram is from the service manual of a combi boiler. It’s a flow sensor which detects whether hot water is running, which is then used to trigger on-demand heat and switch a diverter to take radiators out of the loop.

In English, the diagram shows:

  • X ⅔ red wire (+5V)
  • X 2/2 black wire (ground)
  • X 2/6 green wire (signal)

I need to know what those fractions mean. I took the voltage measurements in this video:

I cannot necessarily trust the model in that video to have the same specs as mine. My voltmeter detected 4.68 V on the red input wire showing that the sensor is well fed. The green “signal” wire is supposed to be 0 V at rest and 2 V with water running (or I think the reverse of that is used in some models). In my case the green wire is ~1.33 V at rest and ~0.66 V when water is running. I need to know if these readings are normal as I troubleshoot this problem.

update


@[email protected] and a couple others gave the answer I was after. Then @[email protected] helped solve the underlying problem. The theory that the sensor was fine but the board was not drove me to test the sensor in isolation. The sensor gave correct output in isolation. Then I connected it back to the motherboard to retest and reconfirm that it’s still broken. But it actually worked. The hot water suddenly and mysteriously works now. I guess the act of draining the water and unplugging the connector then reconnecting and repressurizing caused it to work. It may be temporary, since in the past it was hit or miss whether it would work.

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 1 points 2 months ago

It shows 5V on the diagram but I don’t think that’s precise. I measured the red wire at 4.68v which is around what the guy in the video got in his test. Since the board is part of the circuit I suppose I cannot rule out the board as a problem. Testing the sensor in isolation will be rough going because it’s a proprietary joint. So I would have to get a tight rubber hose and fit that onto a garden hose. For powering it I have a switchable ac adapter with a 4.5 V setting. Or I can maybe get 5V off a USB charger or ATX PSU from a PC. My multimeter does not have a frequency function but I can see from the video that it would be useful for this so I might look for 2nd hand multimeter at the next street market, though that will set me back a week (OTOH might be worth it if it helps diagnose this in a way that helps avoid buying the wrong part).