this post was submitted on 11 Jun 2024
202 points (97.6% liked)

Asklemmy

44151 readers
1691 users here now

A loosely moderated place to ask open-ended questions

Search asklemmy ๐Ÿ”

If your post meets the following criteria, it's welcome here!

  1. Open-ended question
  2. Not offensive: at this point, we do not have the bandwidth to moderate overtly political discussions. Assume best intent and be excellent to each other.
  3. Not regarding using or support for Lemmy: context, see the list of support communities and tools for finding communities below
  4. Not ad nauseam inducing: please make sure it is a question that would be new to most members
  5. An actual topic of discussion

Looking for support?

Looking for a community?

~Icon~ ~by~ ~@Double_[email protected]~

founded 5 years ago
MODERATORS
 

Give us the cheat codes to your industry/place of work!

you are viewing a single comment's thread
view the rest of the comments
[โ€“] [email protected] 1 points 6 months ago (1 children)

Can I pester you with a question? Feel free to tell me to get bent because I know your time is worth money and this is just the internet. We have a new Trane system that was flawless when it was first put in, but over the past five months the blower has started making louder and louder vibration noises. Almost like it's slightly off balance. If it was an older system I wouldn't think twice, but it was dead quiet at first, just the sound of moving air pretty much.

Part of me wants to open up the cabinet and just see if there's some sort of vibration pad that's gotten loose, but I also don't want to to void a warranty, or something. It seems so trivial a thing. We live in the boonies and a service call is pretty onerous for a tech. I thought maybe there could be balancing weights, like a car wheel or a lawnmower blade, but your comment about motors being sealed is making me think twice.

[โ€“] Crashumbc 2 points 6 months ago (1 children)

Opening up the panel to the blower area won't void the warranty. ( not that I would tell anyone you opened it, because disreputable companies will make a stink even though its legal.)

It's possible a mounting bolt came loose (simple fix). There isn't anything to balance on any of the blowers I've ever worked on. So that leaves a bearing going bad in the motor. Or the set-up being out of balance and it destroyed the bearing. Either way, you should put in a call to a company that is authorized to do warranty work on Trane. If your not sure call their 1-800 number and ask them to recommend someone in your area.

Now, if they recommend only replacing the motor I would ABSOLUTELY make them show you the blower running after they replace the motor. So you can see for yourself that the blower isn't out of balance. I've known way to many lazy mechanics that would just replace the motor, because replacing the whole cage is a royal PITA.

[โ€“] [email protected] 1 points 6 months ago* (last edited 5 months ago)

Thank you. It's a new construction and the builder seems to generally pick really good subs, and I'm pretty sure whoever installed it did the entire house, so they should be familiar with it. I'll give them a call.

Edit: Update to this. I cut the circuit breaker and opened the unit and something was clearly wrong with the blower motor. Mountings and bushings etc all looked fine, but rotating the blower manually was rocky. It seems like a bad bearing or something but I'm no expert. The tech came out and confirmed in about 15 minutes the blower motor needs warranty replacement. Unit is less than 8 months old, he said it's rare but he's seen it before. I kind of want to do a teardown but not enough to buy it. Tech said it was OK to run, and I did that up until yesterday when it sounded so bad I was afraid it was going to grenade the whole box and stopped using AC. Temps close to 100F so hopefully he gets to it soon. I'll be sure to have him run it before he leaves. Thanks again.