Hey, thanks for your reply. By serial bulb I mean a incandescent lamp in series with the circuit. I was looking for a cheap and diy option, but I'll take a look on a bench power supply. I still need to get me a decent one anyways.
Ah. It's not going to be possible to size it because the bulb is then acting as a resistor essentially. Unless you know what the equivalent resistance of the circuit you're testing is, and it draws a fixed current, you aren't going to be able to cap the current; Adding a resistor (or bulb) is just going to drop the input voltage and you will probably end up having other issues
Ah got it. Then a bench power supply is the way to go. Thanks again!
Figure 22 has a really cheap voltage and current controlled bench supply using two lm317s from an existing DC supply like a laptop charger etc:
https://www.onsemi.com/pdf/datasheet/lm317-d.pdf
Pre built ones with heatsinks may be available really cheap on eBay too.
If you need a lot of DC power there are some kits on eBay etc. that can convert a PC PSU to a bench supply.